Basic Parameters of the Power Unit

Name of the characteristic Value
1. Lifespan:
- steam-generating nuclear equipment
60 years
2. Power unit output, MW:
- electric (gross)
- electric (net)
- thermal
1.158*) MWE
1.078 MWe
3.200 MWt
3. Unit heat extraction output <300*) MWt
4. Minimum coefficient of installed output utilization > 90%
5. Demand of electric power for own consumption
(including consumption for re-circulating water supplies and construction needs)
7,0*)%
6. Specific heat consumption (gross) 9.932,8*) kJ/kWh
7. Efficiency of the power unit during turbine operation in condensing operating mode:
- gross
- net

36,2*)%
33,7*)%
8. Non-scheduled automatic reactor scram
(less than 1/year)
<0,5
9. Maximum duration of scheduled outages
(refueling, scheduled activities, scheduled repairs) within seven years of operation (the period between two large repairs involving dismantling of the turbine equipment is 8 years at the most)
4 x 16 days
2 x 24 days
1 x 30 days
10. Maximum duration of scheduled maintenance outages (involving dismantling of the turbine equipment) performed every 8 years 40 days
11. Number of operating staff (nominal), workers/MW 0,35
12. Maximum calculation depth of fuel burn-out, average per fuel assembly, for the stationary fuel reload mode 60 MWd/kgU
13. Duration of fuel campaign 4 years
14. Period of refueling 12 months
15. Main coolant parameters:
Primary circuit:
- temperature at core input,
- temperature at core output,
- flow rate through reactor,
- pressure at reactor output.

Secondary circuit:
- steam pressure at SG output,
- steam efficiency of SG,
- temperature of feed water,
-
steam wetness at SG output.


298,2° С
328,9° С
86.000 m3/hr
16,2 MPa


7,0 MPa
1602 t/hr
225° С
< 0,2%
16. General probability of:
- core damage
- excess of the limit environmental impact criteria in case of serious accidents
- total frequency of conditions resulting in serious damage to fuel and containment tightness

<5,8x10-7
<2,0x10-8
<3.7x10-9
17. Reactor hall double containment:
Outer protective steel-concrete containment (resistant to crash of a military or civil aircraft - as required)
- inner diameter,
- height of dome,
- thickness (cylindrical part/dome)

Inner steel-concrete containment with adjustable pre-tensioning
- inner diameter,
- height of dome,
- thickness (cylindrical part/dome),
- calculating overpressure,
- calculating temperature.



50,0 m
70,2 m
0,8/0,6 m


44,0 m
67,6 m
1,2/1,0 m
0,4 MPa
150° С
18. Emergency air cleaning system of containment interspace  from radioactive leakage assures purification, at least:
- elementary iodine,
- organic iodine,
- aerosols.



99,9%
99%
99,99%

*) The parameters will be specified with respect to the turbine island technology chosen by the customer.